My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Reso25 16341
RedwoodCity
>
City Clerk
>
Resolutions
>
City Council
>
2020-2029
>
2025
>
Reso25 16341
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2025 1:50:17 PM
Creation date
7/22/2025 1:47:45 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Resolution
Meeting Type
Regular
Agency Type
City Council
Date
7/21/2025
Jump to thumbnail
< previous set
next set >
Text box
ID:
1
Creator:
REDWOOD_CITY\NANCYRAMIREZ
Created:
7/22/2025 1:50 PM
Modified:
7/22/2025 1:50 PM
Text:
https://www.waterboards.ca.gov/board_decisions/adopted_orders/water_quality/2022/wqo_2022-0103-dwq.pdf
ID:
2
Creator:
REDWOOD_CITY\NANCYRAMIREZ
Created:
7/22/2025 1:50 PM
Modified:
7/22/2025 1:50 PM
Text:
https://www.redwoodcity.org/departments/community-development-and-transportation/engineering-transportation/engineering/engineering-standards
ID:
3
Creator:
REDWOOD_CITY\NANCYRAMIREZ
Created:
7/22/2025 1:50 PM
Modified:
7/22/2025 1:50 PM
Text:
https://www.redwoodcity.org/departments/community-development-department/engineering-transportation/engineering/engineering-standards/volume-1-standard-technical-specifications
ID:
4
Creator:
REDWOOD_CITY\NANCYRAMIREZ
Created:
7/22/2025 1:50 PM
Modified:
7/22/2025 1:50 PM
Text:
https://www.redwoodcity.org/departments/community-development-department/engineering-transportation/engineering/engineering-standards/volume-2-standard-details
ID:
5
Creator:
REDWOOD_CITY\NANCYRAMIREZ
Created:
7/22/2025 1:50 PM
Modified:
7/22/2025 1:50 PM
Text:
https://www.redwoodcity.org/departments/community-development-department/engineering-transportation/engineering/engineering-standards/volume-3-design-criteria
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
320
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DESIGN AND PERFORMANCE PROVISIONS <br />© 2025 Fischer Compliance, LLC. All rights reserved. Sewer System Management Plan licensed for Redwood City use only Page 36 of 59 <br />5. Design and Performance Provisions <br />5.1. Updated Design Criteria/Construction Standards/Specifications <br />WDR REQUIREMENTS <br />Attachment D-5.1 (pg. D-5) <br />“Updated design criteria, and construction standards and specifications, for the construction, <br />installation, repair, and rehabilitation of existing and proposed system infrastructure components, <br />including but not limited to pipelines, pump stations, and other system appurtenances. If existing design <br />criteria and construction standards are deficient to address the necessary component-specific hydraulic <br />capacity as specified in section 8 (System Evaluation, Capacity Assurance and Capital Improvements) of <br />this Attachment, the procedures must include component-specific evaluation of the design criteria.” <br />COMPLIANCE <br />The City’s Engineering Standards were first adopted in 2003 and most recently updated in 2024. <br />Contractors are required to comply, at a minimum, with the Engineering Standards. <br />Volume I- Standard Technical Specifications provides direction for sewer construction, specifications for <br />earthwork, pipe work, manholes, materials, and reinforcement. For example, Section 02 2020 contains <br />specifications for trenching, backfill, pipe bedding and cover material. Section 02730, Part 2.01 contains <br />specifications for pipe material, sizes, and grades. Section 02 7300, Part 2.03 contains specifications for <br />manholes. Section 02 5500 contains specifications for reinforcement and Section 02 7300; Part 3.08 <br />contains specifications for testing of sanitary sewers. <br />Volume II- Standard Details includes the technical drawings associated with the construction of public <br />improvements. <br />Volume III- Design Criteria includes general planning requirements, survey and grading criteria, and sanitary <br />sewer system design criteria for both public and private improvements. <br />EFFECTIVENESS <br />The City utilizes the following Key Performance Indicators for measuring effectiveness of this Element: <br />• Are plan checking QA/QC processes helping to ensure adherence to the standards? <br />IMPLEMENTATION PLAN/SCHEDULE <br />No. Plan Schedule Responsible Party <br /> E&T PWS <br />5.1.1 Ensure all project plans are approved in accordance <br />with the City’s Standard Specifications and Details. Each Project X <br />5.1.2 <br />Verify that design standards and hydraulic model <br />previously completed are adequate and consistent <br />with current standards of practice. <br />Each Project X <br /> <br /> <br />ATTY/RESO.0077/CC RESO SEWER SYSTEM MANAGEMENT PLAN - EXHIBIT A <br />REV: 07-14-25 LF <br /> <br />Page 43 of 317
The URL can be used to link to this page
Your browser does not support the video tag.