My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Agmt25 BKF Engineers -Sanitary Sewer Capacity Improvements Project
RedwoodCity
>
City Clerk
>
Agreements
>
2020-2029
>
2025
>
Agmt25 BKF Engineers -Sanitary Sewer Capacity Improvements Project
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2026 4:34:42 PM
Creation date
12/23/2025 3:16:11 PM
Metadata
Fields
Template:
Agreement
PROJECT NAME
Sanitary Sewer Capacity Improvements Project
RMP File Number
304
Date
12/19/2025
Amendment
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
REV: 11-14-25 LR <br />5. As-Builts: The Consultant shall prepare and submit “As-Built” drawings reflecting <br />all changes and field modifications made during construction. As-Built drawings <br />shall accurately depict the final constructed conditions. The Consultant shall revise <br />the as-built drawings as necessary to address comments or corrections provided <br />by the City and/or contractor until final acceptance by the City. <br />Deliverables: <br />Digital copies of clarification responses and additional design support in native <br />format (PDF, Word) <br />One (1) digital PDF and one (1) native format copy of as-built record drawings <br />Digital copies of final specifications, cost estimate and plans in native format <br />(Word, Excel, and AutoCAD) <br />TASK 9 – POTHOLING (OPTIONAL) <br />As directed by the City, the Consultant and Subcontractor shall perform up to 20 potholes <br />along the project alignment. The Consultant and Subcontractor shall obtain a City <br />encroachment permit and conform to all requirements, including but not limited to the <br />certificate of insurance, traffic control plan, and bonds. Potholing shall conform to the <br />utility trench detail UT-1 of the City Standards and requires permanent restoration. <br />Deliverables: <br />One (1) digital (i.e. AutoCAD, PDF, WORD, etc.) copy of potholing report <br />TASK 10 – GEOTECHNICAL FIELD INVESTIGATION (OPTIONAL) <br />As directed by the City, the Consultant and Subcontractor shall perform a geotechnical <br />field investigation to evaluate the subsurface conditions and develop recommendations <br />for the anticipated trenchless installation beneath the Caltrain tracks at Beech Street. The <br />Consultant and Subcontractor shall drill two (2) test borings to depths of 20 to 25 feet <br />below existing grade near the approximate locations of the proposed jacking and <br />receiving pits along Beech Street. The Consultant shall perform laboratory testing for the <br />sample test borings to determine moisture content, dry density, and plasticity. The <br />Consultant shall provide the City a draft report following the completion of the field work. <br />The final geotechnical investigation scope will be finalized during design and will not be <br />executed without City Engineer or their designee’s approval in writing. <br />Deliverables: <br />One (1) digital (i.e. PDF, WORD, etc.) copy of laboratory test results, draft <br />geotechnical field investigation report and final geotechnical investigation report <br />TASK 11 – HYDRAULIC MODELING (OPTIONAL) <br />As directed by the City, the Consultant shall perform hydraulic modeling to confirm any <br />deviations in proposed pipe diameter from the diameters stated above. The City shall <br />provide the Consultant with a digital copy of the existing sewer model and any information <br />required to run the model based on anticipated sanitary sewer demands. Any <br />recommendations or results generated by hydraulic modeling would be summarized in <br />the Basis of Design (BOD) Report. <br />ATTY/AGR.2025.306/BKF Engineers (Agreement for Service with BKF Engineers) (Page 18 of 19)
The URL can be used to link to this page
Your browser does not support the video tag.