Laserfiche WebLink
ATTY/RESO.0024/PC RESO 901 EL CAMINO <br />REV: 04-11-25 VR <br />Page 18 of 27 <br />on the ground floor of the building at a location subject to the approval of the fire code <br />official. [FIRE] [Redwood City Code of Ordinances §12.23 – 907.2.12.3.1(c) <br />83. Fire Equipment Enclosure - Buildings of four (4) or more stories in height, a secure cabinet <br />or other enclosed area must be provided for housing fire equipment. Fire equipment <br />required to be provided at the direction of the Fire Code Official. [FIRE] [Redwood City Code <br />of Ordinances §12.23 – 907.2.12.3.1(d)] <br /> <br />84. Emergency Responder Radio Coverage -Emergency responder radio coverage is required <br />based upon the existing coverage levels of the public safety communication systems of the <br />jurisdiction at the exterior of the building. [FIRE] <br /> <br />85. Elevator Car to Accommodate Ambulance Stretcher -Where elevators are provided in <br />buildings four or more stories above grade plane, not fewer than one elevator must be <br />provided for fire department emergency access to all floors. The elevator car shall be of <br />such a size and arrangement to accommodate an ambulance stretcher 24-inches by 84- <br />inches with not less than 5-inch radius corners, in the horizontal, open position and shall be <br />identified by the international symbol for emergency medical services (star of life). The <br />symbol cannot be less than 3-inches in height and must be placed inside on both sides of <br />the hoist way door frame. [FIRE] [CBC 3002.4(a)] <br /> <br />86. Car Stacker Fire Protection - If car stackers are utilized, then such car stackers shall be <br />provided with fire protection and smoke removal in accordance with CFC Section 321 as <br />amended by the City of Redwood City Code of Ordinances §12.15.2. [FIRE] <br /> <br />87. Fire Command Center - A Fire Command Center for fire department operations must be <br />provided in buildings classified as high-rise buildings. [CFC §508.1] The Fire Command <br />Center must comply with CFC Sections 508.1.1 through 508.1.7. The construction <br />documents indicate that the Fire Command Center will be smaller than the required 200 <br />ft2. CFC Section 508.1.3 requires that the Fire Command Center be not less than 0.015 <br />percent of the total building area of the facility served or 200 square feet in area, whichever <br />is greater, with a minimum dimension of 0.7 times the square root of the room area or 10 <br />feet, whichever is greater. [FIRE] <br /> <br />88. Fire Command Center AMMR - If the Fire Command Center does not meet Code <br />Requirements as specified in COA #86, then the approved AMMR for the Fire Command <br />Center shall be attached to the plans submitted for a building permit. [FIRE] <br /> <br />89. Rooftop Garden Maintenance Plan Section 317.4.3 of the CFC requires that a maintenance <br />plan be provided to address the vegetation placed on roofs due to the size of a roof garden,