PUBLIC WORKS TEMPLATE FOR INFORMAL BIDDING ($100K) 12-04-25 <br />REV: 12-15-25 MI <br /> <br />2.2 PANEL CONSTRUCTION <br />A. Provide top reinforcement as required to support panel from suspension components and provide <br />reinforcement for hardware attachment. Fabricate panels with tight hairline joints and concealed <br />fasteners. Fabricate panels so finished in-place partition is rigid; plumb aligned, with tight joints <br />and uniform appearance; and free of bow, warp, twist, deformation, and surface and finish <br />irregularities. <br />B. Welded steel panel construction, 3-1/2 inch thick. <br />1. Panels with this construction occur at Community Room. <br />2. Panels at Community Room shall have minimum 18-gauge(1.22-mm) steel face sheets, <br />robotically fusion welded to 16-gauge(1.52-mm) vertical frame members and 14- <br />gauge(1.9-mm) top rail. <br />3. Panel weight not to exceed 7.5 pounds per square foot. <br />4. Panels at Community Room shall be rated minimum 53 STC. If field sound tested, wall/s <br />shall achieve a minimum 42 NIC when tested in accordance with ASTM E336, providing <br />that the surrounding building construction is compatible with this rating. <br />5. Submit test report showing that trolley plate anchorage in test specimen (minimum 4-ft. <br />wide and same construction as proposed for this project) is capable of withstanding a <br />tensile load of 8,000 pounds applied via pendant bolt without failure. <br />6. Submit test report (minimum 4-ft. wide by 20-ft. long test specimen of the same <br />construction as proposed for this project) showing that panel is capable of resisting a <br />uniform load of 20 pounds per square foot applied normal to the panel face without <br />permanent damage when tested in accordance with ASTM E-72. <br />C. Panel Edge Trim <br />1. Panels at Community Room to be furnished with protective vertical edge trim that <br />overlaps the panel face and secures finish at the vertical edge. <br />D. Panel Trim Finish: <br />1. Panels located at Community Room shall have clear satin anodized panel trim. <br />E. Hardware: Manufacturer's standard as required to activate operable panel partition and <br />accessories; with decorative, protective finish to match panel trim finish. <br /> <br />2.3 SEALS <br />A. General: Provide types of acoustical seals indicated that produce operable panel partitions with <br />acoustical performance requirements and the following. <br />1. Seals made from materials and profiles that minimize sound leakage. <br />2. Seals fitting tight at contact surfaces and sealing continuously between adjacent panels <br />and between operable panel partition perimeter and adjacent surfaces, when operable <br />panel partition is extended, closed, and in place. <br />B. Vertical Seals: Deep-nesting, interlocking astragals mounted on each edge of panel, with <br />continuous PVC acoustical seals. <br />C. Top Seals: Panel top seals shall be fixed, flexible multi-fin. <br />D. Horizontal Bottom Seals <br />1. Panels at Community Room shall have mechanical, automatic, retractable bottom seals. <br />Automatic floor seals shall accommodate a minimum 1'' operational clearance between <br />the bottom of the panels and the floor. Seals shall be activated by the movement of <br />panels into final setup position. Bottom seal shall be a cartridge, removable without <br />cutting panel face. <br /> <br />2.4 FINISH FACING <br />A. General: Provide finish facings that comply with indicated fire-test-response characteristics and <br />that are factory applied to operable partitions with appropriate backing, using mildew-resistant <br />non-staining adhesive. <br />1. Apply one-piece facings free from air bubbles, wrinkles, blisters, and other defects, with <br />no gaps or overlaps. Tightly secure and conceal raw and selvage edges of facing for <br />finished appearance.