My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Agmt12 Furgo Consultants, Inc.
RedwoodCity
>
City Clerk
>
Agreements
>
2010-2019
>
2012
>
Agmt12 Furgo Consultants, Inc.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2014 3:48:24 PM
Creation date
9/21/2012 9:36:09 AM
Metadata
Fields
Template:
Agreement
Contractor Name
Furgo Consultants, Inc.
PROJECT NAME
Phase II Environmental Site Assesment 1306 Main St
RMP File Number
304.5
Date
9/20/2012
MO Ref
MO 14-054 for amendment No 1 4/21/14
Amendment
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
disposal as a non-hazardous waste. Consultant will use the results of chemical analyses to coordinate <br /> disposal of the drummed waste. <br /> Analytical Testinq Proqram <br /> All chemical testing will be competed using standard 7 to 10 day turnaround time. If needed, quicker <br /> turnaround can be arranged subject to a laboratory surcharge. Two soil samples and one grab <br /> groundwater sample from each probe will be tested for some or all of the following: <br /> Total Petroleum Hydrocarbons as gasoline (TPHg) and benzene, toluene, ethyl benzene, <br /> and xylenes using EPA Test Method 8015m/8020/8260 (6 soil and 3 water samples), <br /> Total Petroleum Hydrocarbons as diesel fuel (TPHd) and motor oil (TPHmo) using EPA <br /> Test Method 8015m with silica gel cleanup (6 soil and 3 water samples), <br /> VOCs using EPA Test Method 8260 (3 soil and 3 water samples), and <br /> 17 Title 22 heavy metals using EPA Test Method 6010/7471 (2 soil) and Total lead using <br /> EPA Test Method 6010 (6 soil). For budgetary purposes, we have also assumed that <br /> two samples may be tested for soluble metals using WET and TCLP methods. <br /> Data Evaluation and Optional Sub-Slab Samplinq <br /> Data will be tabulated and compared to environmental screening criteria to assess whether there is a <br /> potential for risks to be posed to property users. Potential vapor intrusion risks to site users due to <br /> positively detected volatile organic compounds will be assessed by conducting a Tier II data evaluation <br /> using risk modeling software developed by Johnson and Ettinger, as modified by the California <br /> Environmental Protection Agency (CaIEPA). In the event that a vapor intrusion risk is posed consultant <br /> will contact you to determine whether additional field data needs to be collected prior to preparing our <br /> investigation report. Subsequent studies may involve collection of vapor samples from below the <br /> existing building slab and conducting additional Tier II data evaluations. <br /> Reportinq <br /> Results of consultanYs inquiries regarding utility alignments, consultant's current review of <br /> environmental data presented on GeoTracker and Envirostor databases, field observations, results of <br /> chemical analyses, and Tier II data evaluations will be summarized in a written report. The report will <br /> include consultant's conclusions and recommendations regarding the regulatory status of the various <br /> known and existing conditions in the area, and consultant's opinion regarding whether residual <br /> contamination represents a potential risk to future site uses. Consultant will provide a draft of the <br /> report to you for review and comment. Consultant will address your comments, and then issue a final <br /> report for your use. <br /> FEE AND SCHEDULE <br /> Consultant will provide the services described herein on a time-and-materials basis in accordance with <br /> the attached Fee Schedule for an estimated fee of$31,000, which includes $3,000 for City of Redwood <br /> City permitting and fees. These fees are approximated as the City will not provide a cost estimate for <br /> the fees until they are provided with a plan and application for the work. The attached table itemizes <br /> our fee estimate for the tasks described above, and the optional tasks ($12,000) in the event that the <br /> initial data shows a modeled potential vapor intrusion risk to site users. <br /> Subject to permit approval and driller availability, consultant will complete the initial site work within <br /> about 6 weeks of your authorization to proceed. Drilling and sampling operations will be completed <br /> over a 1-day period; a second day would be needed if interior sub-slab samples are required. <br /> ATTY/AGR/139/1306 MAIN STREET PHASE II ENVIRONMENTAL SITE ASSESSMENT <br /> REV:09-07-12 VR <br /> Page 11 of 13 <br />