Laserfiche WebLink
EXHIBIT "B" <br />ON BROADWAY - PARHING GARAGE <br />CLARIFICATIONS & EXCLUSIONS <br />Sofa <br />7600 SHEET METAL • Not used. <br />7800 ROOF Not used. <br /> ACCESSORIES <br />7900 JOINT SEALANTS Included miscellaneous caulking. <br /> & CAULKING Caulking at SOG floorjoints is excluded. <br /> • Bond for caulkin subcontractor is excluded. <br />8100 DOORS, FRAMES Assumed hollow metal doors with punched & dimpled frames. <br /> & FINISH • Assumed 2 EA Electrical room doors & frames. <br /> HARDWARE Assumed 6 E.A Mechanical room doors & frames. <br /> • Assumed 6 EA Stair enclosure doors & frames. <br /> • Assumed 1 EA Attendant room doors with frame for wire glass & <br /> frame. <br /> • Assumed Schlage commercial grade finish hardware with brushed <br /> chrome finish. <br /> • Any electronic or non-key type hardware is excluded. <br /> • Card access system is excluded. <br /> • Bond for door & frame subcontractor is excluded. <br />8360 OVERHEAD DOOR • Included 1 overhead grill at garage entry. <br /> • Bond for overhead door subcontractor is excluded. <br />8800 GLASS & • Provided wire glass at garage Attendant Office door. <br /> GLAZING • Bond for lass & ~lazin subcontractor is excluded. <br />9210 LATH & PLASTER Not used. <br />9260 DRYWALL & • Provided vertical framing and GWB soffits at outside of stairway <br /> METAL STUD enclosures. <br /> FRAMING Provided framing &GWB at Attendant restroom. <br /> • Bond for GWB & metal stud subcontractor is excluded. <br />9310 CERAMIC TILE • Not used. <br />9510 ACOUSTICAL • Acoustical ceiling provided at Attendants Office. <br /> CEILING - • Bond for Acoustical Ceilino subcontractor is excluded. <br />9660 RESILIENT FLOOR • Standard VCT at Attendant's Office is included. <br /> • Flooring at stairs or other areas is excluded. <br /> • Bond for floorin subcontractor is excluded. <br />9815 FLOOR SEALER Floor sealer at SOG or elevated decks is excluded. <br />9900 PAINTING • The following painting using acrylic sealer and paint is included: <br /> • CMU (garage side only). <br /> • Attendant Office interiors. <br /> ^ Soffits @ Stair perimeters. <br /> ^ Concrete ceilings @ lower and upper levels including pipes. <br /> ^ Garage concrete columns & walls. <br /> ^ GWB soffits. <br /> • Exposed misc. metals to be painted with 2-coat rust inhibiting <br /> process. <br /> • Metal pan stairs to be painted with alkyd industrial enamel. <br /> • Hollow metal doors & frames to be painted with acrylic semi-gloss <br /> enamel <br /> • Murals and artwork are excluded. <br /> • Bond for aintin subcontractor is excluded. <br />10000 MISC. • Fire hose cabinets are excluded. <br /> SPECIALITIES • Provided 71 EA tire extinguishers and surface mounted, prefinished <br /> cabinets. <br /> • Provided 1 Knox box. <br />