Laserfiche WebLink
EXHIBIT "B" <br />ON BROADWAY - PARHING GARAGE <br />CLARIFICATIONS & EXCLUSIONS <br />6of8 <br /> • Sound or intercom system is excluded. <br /> • Bond for misc. s ecialt subcontractor is excluded. <br />10160 TOILET • Included Bobrick or similar toilet accessories at Attendant's Office <br /> ACCESSORIES & that includes surface mounted grab bar, seat cover dispenser, <br /> PARTIONS combination TP & sanitary napkin disposal, mirror, PT & waste <br /> disposal. <br /> • Toilet partitions are excluded. <br /> • Bond for toilet accessor subcontractor is excluded. <br />10430 SIGNAGE Included an Allowance of $40,000 for way findin / si nage. <br />10538 AWNINGS Not used. <br />11500 PARKING ACCESS • Parking and access control systems are excluded. <br /> CONTROL <br /> SYSTEM <br />14200 ELEVATORS • Provide 2 EA - 3 stop holeless, 3,500 #, 150 FPM elevators for <br /> garage. <br /> • Included an Allowance of $25,000 for finishes. <br /> • Bond for elevator subcontract is included. <br />15400 DESIGN BUILD • Provided a 500 gallon sand /oil separator. <br /> PLUMBING • Provided RI & trim for plumbing at Attendant toilet. <br /> • Provided elevator sump pumps & pit drains. <br /> • Provided garage sump pump for garage area drains only. <br /> • Provided 24 EA garage area drains 1 EA trench drain 8c 9 EA floor <br /> drains. <br /> • Provided 4 EA hose bibs. <br /> • Wall hydrants /hose bibs at stairways or interior columns are <br /> excluded. <br /> • Plumbing to be Design /Build. <br /> • Bond for Plumbino subcontractor is included. <br />15500 DESIGN BUILD • Assume sufficient flow and pressure provided by City water system. <br /> FIRE • Provide backflow preventors on the inside of building, sufficient <br /> PROTECTION space to be allowed for backflow to be provided in design of garage. <br /> • Provide FDC on street level. <br /> • Garage heads to be extended coverage upright heads. <br /> • Fire hoses, hose valves and cabinets are excluded. <br /> • Fire pumps are excluded. <br /> • System designed to meet NFPA codes and excludes any Factory <br /> Mutual or other ratings agency requirements or review. <br /> • Bond for Fire Protection subcontractor is included. <br />15800 DESIGN BUILD Provided fully ducted exhaust system at rate of 1.5 CFM / SF using <br /> HVAC centrifugal exhaust fans with variable speed drives and manual bypass <br /> panel. Exhaust shafts to have one fan per shaft mounted at upper <br /> garage. <br /> • Exhaust fans to be spring mounted and installed with sound traps. <br /> • Exhaust to be vertically ducted to roof. <br /> • Make up air to be fully ducted. <br /> • Exhaust system controlled by carbon monoxide detection system with <br /> coverage of 1 / 5,000 SF. Detection system to ramp exhaust fans <br /> from SO PPM (0 speed) to 200 PPM (100%). CO panels to have <br /> audible and visual alarms. <br /> • Provide A/C systems for Attendant Office and elevator machine <br /> rooms. <br /> + Provide elevator positive pressure at Elevator Lobbies. <br />