My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
AgdaPkt 2013-03-11
RedwoodCity
>
City Clerk
>
Agenda Packets
>
2010-2019
>
2013
>
AgdaPkt 2013-03-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/12/2013 4:28:35 PM
Creation date
3/7/2013 4:37:19 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Agenda Packet
Meeting Type
Regular
Agency Type
City Council
Date
3/11/2013
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
921
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Proposed Costco Wholesale Redwood City GDF Expansion 7.A. - Page 156 <br /> Air Quality/Climate Change Analysis <br /> Page 22 <br /> Table 13. Comparison of Queuing Emissions for the Proposed GDF Expansion to the 2007 <br /> Certified EIR GDF. <br /> Queuing Emissions Queuing Emissions Comparison of <br /> Reflected in 2007 Estimated for Proposed Proposed GDF <br /> Certified EIR Expansion Expansion to 2007 <br /> (16 Positions) (20 Positions) Certified EIR GDF <br /> Pollutant (pounds/day) (pounds/day) (percent) <br /> Carbon Monoxide 4.6 3.2 70% <br /> Nitrogen Dioxide 0.5 0.29 58% <br /> Respirable Particulate 0.04 0.01 25% <br /> Matter(PM�o) <br /> (Source: Appendix C.) <br /> Odors. <br /> The 2007 Certified EIR noted that the GDF is a potential odor source due to evaporative <br /> emission losses from gasoline dispensing at the facility, but that such odors are generally <br /> readily dissipated within the breezy conditions of Redwood City. As noted in the 2007 Certified <br /> EIR, the GDF is required to install and operate emissions controls to reduce emissions of <br /> gasoline vapors. The combined effect of emissions controls, distance setbacks, and generally <br /> favorable wind conditions were expected to minimize potential odor impacts to less than <br /> significant levels. Costco will be required by the Bay Area AQMD to install emissions controls <br /> on its new fuel dispensers to reduce emissions of gasoline vapors, conduct emissions source <br /> testing to verify correct operation, and perform ongoing maintenance to ensure continued <br /> operation. Also, the Bay Area AQMD has received no odor complaints against the Costco <br /> Redwood City GDF since it began operation in September 2009 (Source: BAAQMD, 2012). <br /> Therefore, potential odor impacts associated with operation of the proposed 20-position GDF <br /> are expected to remain less than significant. <br /> Toxic Air Contaminants. <br /> Proiect Impacts. In February 2008, the Bay Area AQMD conducted a health risk screening <br /> analysis, using dispersion modeling, to evaluate the potential health risks associated with the <br /> proposed Costco Wholesale Redwood City GDF (BAAQMD, 2008b). Assuming a gasoline <br /> throughput of 29.8 million gallons per year (the maximum allowable throughput without requiring <br /> emission offsets under the District's New Source Review Rule), the District estimated excess <br /> cancer risks and chronic non-cancer hazard indices to be as shown in Table 14. <br /> Table 14. Summary of Bay Area AQMD Health Risk Screening Analysis for Costco Redwood <br /> City GDF (29.8 million gallons/year throughput). <br /> Receptor Excess Cancer Risk Chronic Non-cancer Health Index <br /> Resident 2.0 per million 0.001 <br /> Worker 2.7 per million 0.008 <br /> Student (Hoover 0.06 per million 0.0006 <br /> Elementary School) <br /> 7/30/2012 <br />
The URL can be used to link to this page
Your browser does not support the video tag.